1. Image Quality Problems

- Pattern 4
[Cause]
The media is slantingly advanced.
   
  • Depending on the situation, perform a combination of the solutions below.

• Check that the media on the roll is straight. If is not, replace it.


• Check that the media is traveling straight off the roll.
If not, adjust the position of the flange holder or shift the media right or left by raising the Pressure roller up/down lever to set the media vertically. In addition, when using the take-up reel unit, adjust the position of flange at the take-up side or re-set the media.


• Confirm that the media is loaded straight against the flange.


• If the media is under the entire pressure roller, release the pressure force of pressure roller.

If the media with the flange installed is stood on end, the
media alignment on the roll will become the source of a
possible problem.